VS Pump Efficiency Calculator

DEEP END FRANK

Pump Efficiency Calculator

Compare schedules using published test points, your readings, or a teaching example.

17.0¢ per kWh
Published baselines. Estimated schedules. Choose a specific documented pump, enter your own operating readings, or explore a clearly labeled hypothetical example. Horsepower alone cannot predict GPM or watts. This calculator estimates changes with affinity laws; it does not reproduce Jandy's savings calculator or predict your installation precisely.

Half speed. Twice the time. One-quarter the energy.

½speed & approximate flow
⅛estimated power
2×time for the same gallons
¼energy for the same gallons

In the ideal affinity-law model, that is 75% less energy to move the same water volume. Real electrical savings vary with pump and motor efficiency. Verify adequate flow for skimming, circulation and equipment.

Compare fairly: same gallons moved

How to use this for your pool

1. Enter pool gallons and your electricity rate in dollars: 17 cents is 0.17.

2. Select a published model or "Your operating readings." For your own readings, enter RPM, GPM and electrical input watts measured together with the same valve arrangement. A watt display alone cannot determine flow. Single-speed pumps of any horsepower can be compared using their actual readings; we do not invent values based on HP.

3. Adjust RPM and daily hours. Add periods for skimming, cleaning, water features or longer low-flow operation. Total runtime must be no more than 24 hours per pump. A single-speed pump stays at its reference RPM.

4. Check the same-gallons comparison below. Different daily schedules can move different volumes, so their daily costs alone do not establish efficiency.

5. Verify whole-pool circulation, skimming and flow requirements for salt cells, heaters and cleaners. A schedule that moves enough total gallons can still fall short of an equipment requirement.

What the numbers mean

GPM: gallons per minute. Gallons per hour: GPM × 60. Daily gallons: sum of GPM × 60 × hours. Turnovers: daily gallons ÷ pool gallons. Mixing means one turnover does not guarantee every gallon passes through the filter once.

Daily energy: sum of watts ÷ 1,000 × hours. Daily cost: kWh × rate. Monthly cost: daily cost × 30. These costs include only the filter pump, excluding boosters, salt systems, heaters, taxes and fixed charges.

Same-gallons comparison: scales Pump B's period hours proportionally to match Pump A's daily gallons. More than 24 hours makes that comparison infeasible as a one-day schedule. Equal gallons do not prove equal filtration quality, skimming, mixing or chemistry distribution.

Sources, test points and estimate limitations

Documented model presets: the following high-speed test points come from the official EPA ENERGY STAR certified pool pump dataset, retrieved October 6, 2026. These are laboratory operating points, not average-pool readings and not necessarily maximum-speed points. Values are specific to the exact listed model and reported test condition.

Official EPA dataset (CSV) · EPA field definitions · Download this calculator's reference data

Affinity-law estimate: Q₂ = Q₁ × (N₂/N₁), H₂ = H₁ × (N₂/N₁)², and P₂ ≈ P₁ × (N₂/N₁)³. N is RPM, Q is flow, H is head, and P is electrical watts here. The electrical-power calculation assumes constant efficiency; actual drive, motor and hydraulic efficiencies vary. Baseline values are sourced or entered; values at other RPM are estimates, not additional measured test points. Even other published points may differ from this ideal scaling.

TDH: total dynamic head is resistance at a particular flow. It falls approximately with the square of speed in this friction-dominated example; it is not fixed at every RPM. We do not adjust a documented baseline with a generic TDH slider: an accurate change of system resistance needs the pump's actual curve and system curve. The hypothetical example uses 50 ft only as an assumed reference head, not a verified industry average. Your optional measured reference TDH is for context and is not used to alter flow or watts.

Hypothetical teaching example: 3,450 RPM, 120 GPM, 2,500 W and 50 ft reference TDH. It is an invented operating point for demonstrating the math, not the average performance of a real pump or HP category.

Limits: unchanged plumbing and valve settings, friction-dominated head and constant efficiency are assumed. Static lift, solar systems, water-feature branches, filter loading and equipment flow thresholds can change the result. Very low-speed estimates can understate electrical power because real pumps have losses and minimum power consumption. Standby energy is excluded. Do not use this estimate as a purchase guarantee or a final operating schedule.

Reference: U.S. Department of Energy: pump affinity laws and efficiency limitations. This is an independent educational tool, not affiliated with or endorsed by Jandy or EPA.

Deep End Frank · Estimated results, rounded for planning. Confirm actual flow, input watts and equipment requirements.